Classification: Biological Diagnostics
Type: Erythrocyte Sedimentation Rate Analyzer
Group: All
Reading Channels: 20
Sample Interval: 3 Minutes
Measurement Range: (1-140)mm/H
Samples:
US$ 535/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (23)

Basic Info.

Model NO.
BK-ESR20
Measuring Time
30 Minutes or 60 Minutes Selectable
Reading Resolution
0.1mm
Display
LCD Display
Interface
RS-232
Storage
4,000 Results
Print
Built-in Thermal Printer
Analysis Result
Westergren ESR Value(mm/Hr)
Transport Package
Wooden Case or Carton Package
Specification
380*700*460mm
Trademark
Biobase
Origin
China
HS Code
902780
Production Capacity
1000unit/Month

Product Description

BIOBASE Auto ESR Analyzer
BK-ESR20
Biobase Erythrocyte Sedimentation Rate Analysis 80t/H 40 Channels Auto ESR Analyzer
Biobase Erythrocyte Sedimentation Rate Analysis 80t/H 40 Channels Auto ESR Analyzer
 

Introduction:
ESR testing has important guiding significance for many clinical diseases, but the traditional standard Westergren method has complicated operation, low work efficiency and large cross-contamination. Automatic ESR analyzer uses advanced infrared light color difference interpretation technology to automatically scan the whole process of red blood cell sedimentation within 30 minutes for the sample of the vacuum blood collection tube, and refer to the Westergren method to measure the standard curve to obtain accurate results.

 * Parameters

Model
BK-ESR20
BK-ESR40
Application
Erythrocyte sedimentation rate analysis
Measurement Method
Infrared detection
Analysis Result
Westergren ESR value (mm/hour)
Throughput
Maximum 40 tests/hour
Maximum 80 tests/hour
Analysis Channels
20 (load up to 20 samples for analysis at the same time)
40 (load up to 40 samples for analysis at the same time)
Loading Type
Load samples at any time, measure at any time
Analysis Time
30 minutes or 60 minutes selectable
Sampling Interval
3 min
Measurement Range
0~150mm/h
Temperature Compensation
The result is automatically corrected to the result at 18°C
Result Resolution
1mm/1h and 1mm/2h
Blood Level Range
46mm~64mm
HCT Range
0.2~1.0
Repeatability
0~10mm/h, SD≤1.5mm/h;
>10mm/h, CV≤15%
Channel Consistency
0~10mm/h, SD≤1.5mm/h;
>10mm/h, CV≤15%
Reading Accuracy
0.2mm
Coincidence
≥90%
Display
7-inch color LCD touch screen
Communication Interface
RS232 serial interface
Printer
Built-in thermal printer
Power Supply
AC100~240,220V 50/60Hz
External Size (W* D*H)
260*230*190mm
360*300*180mm
Net Weight
4.9kg
7.3kg
Package Size (W* D*H)
310*270*340mm
395*335*375mm
Gross Weight
7.2kg
10kg
 * Features
Features:
1. 7-inch color touch LCD screen, easy to operate, high resolution
2. 80 samples/hour, rapid detection
3. Randomly insert sample positions for testing at any time
4. Built-in thermal printer for easy data printing
5. Results are automatically temperature compensated
6. Advanced optical testing principles to overcome reading errors in manual methods
7. Power-off save function, automatically save the test results


 * After Sale and Company
Biobase Erythrocyte Sedimentation Rate Analysis 80t/H 40 Channels Auto ESR Analyzer
Biobase Service

Pre-sale service
* Sales are online anytime
* Multi-language is available
* Upate new arrival


20 years of export products
Best Price and Good 


Professional after-sales team is always online
* Solve the problem
* Installation guide 
 
 * Factory and Certificates
Biobase Erythrocyte Sedimentation Rate Analysis 80t/H 40 Channels Auto ESR Analyzer
Biobase Erythrocyte Sedimentation Rate Analysis 80t/H 40 Channels Auto ESR Analyzer
  
 * Main Product

BIOBASE, Founded in 1999 and been through high and stable development for 20 years.

Main Products: Biological Safety Cabinet, Fume Hood, Laminar Flow Clean Bench, Refrigerator, Incubator, Autoclave, Centrifuge etc.

Overseas Office: USA Branch Office, Indian Branch Office, Dubai Branch Office.
Biobase Erythrocyte Sedimentation Rate Analysis 80t/H 40 Channels Auto ESR Analyzer
 * Contact Us

Biobase Erythrocyte Sedimentation Rate Analysis 80t/H 40 Channels Auto ESR Analyzer

Looking forward to our cooperation, always online.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
320
Year of Establishment
2017-02-08