Biobase Standard Curve Generation Lab Spectrophotometer

Product Details
After-sales Service: Online Technical Service
Application: Laboratory Apparatus
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Biobase Standard Curve Generation Lab Spectrophotometer
  • Biobase Standard Curve Generation Lab Spectrophotometer
  • Biobase Standard Curve Generation Lab Spectrophotometer
  • Biobase Standard Curve Generation Lab Spectrophotometer
  • Biobase Standard Curve Generation Lab Spectrophotometer
  • Biobase Standard Curve Generation Lab Spectrophotometer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Our Main Products
  • FAQ
  • Exhibition&Service
  • Packaging & Shipping
  • Contact Bailie
Overview

Basic Info.

Model NO.
BK-UV1800
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
New Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Polychromator
Customized
Non-Customized
Optical System
Single Beam, Grating 1200 Lines/mm
Wavelength Range
190~1100nm
Spectral Bandwidth
2nm
Wavelength Accuracy
± 0.5nm
Wavelength Repeatability
≤ 0.3nm
Noise
± 0.0005A
Display
480 * 272 65 Thousand True Color TFT LCD
Photometric Mode
T, a, C, E
Photometric Range
0~200% T, -0.301~3.0A
Detector
Silicon Photodiode
Gross Weight (Kg)
18
Brand
Biobase
Color
White
Transport Package
Wooden Box
Specification
620*500*370mm
Trademark
BIOBASE
Origin
China
Production Capacity
300units/Month

Product Description

Product Description
Biobase Standard Curve Generation Lab Spectrophotometer
Features:
1. With GLP self-check function, check the wavelength accuracy and Photometry accuracy.
2. Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically.
3. With Si02 coating optical mirror, reducing the pollution from outside fully.
4. PC Software to expand the applications to Quantitative, Multi-Wavelength and Kinetics, Spectrum Scanning, DNA/Protein test for PC Series.

 

Basic Functions:

1, Photometry

Test Abs., Transmittance and Energy by fixed wavelength

2, Quantitative

Linear fit and Linear fit through zero two modes

a. Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve            

b. Establish A=K1*C+K0, can search original data, graph curve, parameters settings

c. Can save 240 group curves, can test 240 data in each curve

d. Double wavelength, Triple wavelength test functions

3, Kinetics

Used for time course scanning or reaction ratecalculations△A/t,can search all data.  

4, Multi-Wavelength

Can test Transmittance and Abs. with 8 different wavelengths at most

 

Product Parameters

Model

BK-UV1800

BK-UV1800PC

BK-UV1600

BK-UV1600PC

BK-V1800

BK-V1800PC

BK-V1600

BK-V1600PC

Optical System

Single Beam, Grating 1200 lines/mm

Wavelength Range

190~1100nm

320-1100nm

Spectral Bandwidth

2nm

4nm

2nm

4nm

Wavelength Accuracy

± 0.5nm

Wavelength Repeatability

≤ 0.3nm

Photometric Accuracy

± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.5% T (0~100% T)

Photometric Repeatability

0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T)

Stray Light

≤ 0.05% T @ 360nm; 220nm

≤ 0.05% T @ 360nm;220nm

Stability

± 0.001A / h @ 500nm

Baseline Flatness

± 0.002A

Noise

± 0.0005A

Display

480 * 272 65 thousand true color TFT LCD

Photometric Mode

T, A, C, E

Photometric Range

0~200% T, -0.301~3.0A

Detector

Silicon Photodiode

Light Source

Lamp, Tungsten Lamp

Input

Membrane Keypad

Output

USB  Print and data output, Connect PC

Standard Accessories

10mm glass cuvette *4 units       10mm quartz cuvette *2 units

10mm glass uvette *4 units

Optional Accessories

Single cell holder,General cell holder,Test tube holder,Solid sample holder,Halogen lamp,4-place Cell holder,Printer,Water-jacketed cell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system

 

4-place Cell holder,Printer, Test tube holder,Halogen lamp

 

Power Supply

AC110V/220±10% ,60/50Hz

Packing Size(mm)

620*500*370

620*500*370

620*500*370

620*500*370

Gross Weight (kg)

18

18

16.5

16.5

Company Profile

Biobase Standard Curve Generation Lab Spectrophotometer

Our Main Products

Biobase Standard Curve Generation Lab Spectrophotometer

FAQ

1.Why choose BIOBASE?
We are the leading manufactuer in lab furniture and lab equipment, OEM & ODM service are offered. And we have our own overseas techinican and installation team.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3. When can I get the price?
We usually quote as soon as we get your inquiry. If you need urgent reply, please tell us your email or Skype account, we will contact you ASAP.
4. What can you buy from us?
Laboratory Equipment (Biological Safety Cabinet,Fume Hood,Laminar Flow Cabinet,Autoclave,Freezer and Refrigerator)
5. Why should you buy from us not from other suppliers?
BIOBASE group, founded in 1999 and been through high and stable development for 15 years, who is now with revenues of one hundred million, 1200 employees in China and abroad offices, 22.4 acres land industry parks and 20000 square meters production base.

Exhibition&Service

Biobase Standard Curve Generation Lab Spectrophotometer

Packaging & Shipping

Biobase Standard Curve Generation Lab Spectrophotometer

Contact Bailie

Biobase Standard Curve Generation Lab Spectrophotometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More