High Performance Liquid Chromatography-BK1100
Features:
*LCD display
*Front-mounted self-locking switch
*Small size, easy to place, save space
*Standard configuration USB portspace
Model |
BK-LCI1100 |
BK-LCG1100 |
|
High Pressure Constant Flow Pump |
Double plunger reciprocating pump |
1 set |
2 sets |
Flow Range |
0.001mL/min-10.000mL/min |
||
Setting Step Size |
0.001mL/min |
||
Flow Accuracy |
≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) |
||
Flow stability |
RSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) |
||
Maximum Pressure |
42MPa |
||
Display Pressure Error |
≤±3.0% |
||
Pressure Fluctuation |
≤1.0% |
||
Power Dissipation |
80W |
||
UV/VIS Detector |
Wavelength Range |
190-700nm |
|
Wavelength Repeatability |
±0.1nm |
||
Wavelength Accuracy |
≤±1.0nm |
||
Spectrum Band Width |
8nm |
||
Response Time |
0.0s-4.9s |
||
Linearity Range |
1.8AU (5%) |
||
Baseline Noise |
≤±1×10-5AU |
||
Baseline Drife |
≤2.0×10-4AU/h |
||
minimum Detectable Concentration |
4.0×10-9g/mL(Naphthalene in Methanol Solution) |
||
Detector Cell |
Optical Path--10mm, Volume--10μL |
||
Light Source |
Deuterium Lamp |
||
Power Dissipation |
100W |
||
Gradient Mixer |
/ |
GM1100 |
|
Sampler Injector |
1 |
||
Supersil ODS2 5μm ID4.6×200mm |
1 |
||
Workstation (Without Computer & Printer) |
1 |
||
Valve Mounting Frame |
1 |
||
Kits |
Isocratic System Kits |
Gradient System Kits |
|
Power Supply |
AC110/220V±10%, 50/60Hz |
||
Optional Accessory |
Column Oven |
Features:
* Adopting mature and reliable mechanical structure, optical structure and circuit structure of core technology
* Stepper motor 64 subdivision control technology to improve accuracy at low flow rates
* Straight-through pressure transmitter
* Scientific air duct design to effectively reduce baseline drift
Technical Parameters:
Model |
BK-LCI3100 |
BK-LCGH3100 |
BK-LCQL3100 |
|||
High Pressure Constant Flow Pump |
Quantity |
1 Set |
2 Set |
1 Set |
||
Flow Rate Range |
0.001mL/min-10.000mL/min |
|||||
Flow Accuracy |
≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) |
|||||
Flow Precision |
RSD≤0.075% (1.00ml/min, H2O,R.T.,8.5MPa) |
|||||
Maximum Pressure |
45MPa |
|||||
Pressure accuracy |
≤±3.0% |
|||||
Pressure pulsation |
≤0.1MPa |
|||||
UV/VIS Detector |
Wavelength Range |
190-700nm |
||||
Wavelength Repeatability |
≤0.1nm |
|||||
Wavelength Accuracy |
≤±1.0nm |
|||||
Band Width |
8nm |
|||||
Response Time |
0.0s-5s |
|||||
Baseline Noise |
≤±0.5×10-5AU |
|||||
Drift |
≤1.0×10-4AU/h |
|||||
Path length |
10 mm(analytical cell) |
|||||
Light Source |
Deuterium Lamp |
|||||
Low-Pressure Gradient Unit |
Integrated vacuum degasser |
/ |
/ |
4 channel |
||
Composition Rang |
0-100% |
|||||
Composition Precision |
≤0.2% RSD |
|||||
Composition Accuracy |
≤±2.0% |
|||||
Data-processing Workstation |
Internal and external standard calculation methods Automatically displays, prints, exports and starts other programs after the completion of a measurement. |
|||||
3100 System Kits |
1 Set |
|||||
Power Supply |
AC110/220V±10%, 50/60Hz |
|||||
Optional Accessory |
Column Oven, Autosampler, Degasser, Diode Array Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector |
|||||
Package Size(W*D*H) |
600*440*380mm*4 |
|||||
Gross Weight |
68kg |
High Performance Liquid Chromatography- BK5100
Features:
*Highly integrated ARM microcontroller SPI, I2C technology
* Accurate automatic wavelength positioning and excellent wavelength accuracy
* Plunger floating design, more stable output
* Intelligent sequence analysis and batch processing
* Chromatography workstation software meets 21 CFR Part 11
Technical Parameters:
Model |
BK-LCI5100 |
BK-LCG5100 |
BK-LCQL5100 |
|
Pump |
Type |
Isocratic Pump |
Gradient Pump |
Quarternary Low Pressure Pump |
Flow Rate Range |
0.001-10.000mL/min, in 0.001mL increments |
|||
Flow Accuracy |
≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) |
|||
Flow Precision |
RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa) |
|||
Maximum Pressure |
63MPa |
|||
Pressure accuracy |
≤±3.0% |
|||
Pressure pulsation |
≤0.1MPa |
|||
Composition rang |
/ |
0-100% |
0-100% |
|
Composition precision |
/ |
≤0.2%RSD |
≤0.3%RSD |
|
UV/VIS Detector |
Wavelength Range |
190-800nm |
||
Wavelength Repeatability |
≤0.1nm |
|||
Wavelength Accuracy |
≤±1.0nm |
|||
Band Width |
6nm |
|||
Response Time |
0.0s-5s |
|||
Baseline Noise |
≤±0.25×10-5AU(empty cell, 254nm, 1.0s) |
|||
Drift |
≤0.5×10-4AU/h(empty cell, 254nm, 60min) |
|||
Path length |
10 mm(analytical cell) |
|||
Light Source |
Deuterium Lamp and Tungsten Lamp |
|||
Data-processing Workstation |
Sequence tables for any set of samples Internal and external standard calculation methods Automatically displays, prints, exports and starts other programs after the completion of a measurement. |
|||
5100 System Kits |
1 Set |
|||
5100 System Manager |
Integrated A/D converters |
Integrated A/D converters Integrated vacuum degasser, 4 channel |
||
Power Supply |
AC110/220V±10%, 50/60Hz |
|||
Optional Accessory |
Solvent bottle,Column Oven, Auto-sampler,DAD512 Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC |
|||
Package Size(W*D*H) |
700*570*310mm; 700*570*350mm; 710*583*500mm; 730*450*440mm; 600*440*380mm; 770*450*700mm; |
|||
Gross Weight |
156kg |