• Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
  • Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
  • Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
  • Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
  • Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
  • Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System

Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System

Classification: Biological Diagnostics
Type: Nucleic Acid Extractor Extraction System
Certification: CE, ISO13485
Group: All
Product Name: Nucleic Acid Extraction System
Sample Capacity Screen: 10.1 Inch Touch
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (23)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Company Profile
  • Contact me
Overview

Basic Info.

Model NO.
BNP96
Sample Volume
20-1000
Sample Capacity
1-96
Magnetic Bead Recovery
≥98%
Extraction Time
15- 40 Minutes
Extracting The Differece Between Holes
CV≤3%
Consumption
500W
Operating Temperature
Rt-120 ºC
Product Purity A260/A280
DNA≥1.7-2.0; Rna≥1.8-2.1
Shock Mlixing
Adjustable Speed (1-3)
Reagent Type
Open System for Magnetic Bead Method
Power Supply
AC100V-240V 50Hz/60Hz
External Size(W*D"H)
770*530"540mm
Gross Weight
95kg
Transport Package
Wooden Case or Carton Package
Specification
910*670*780mm
Trademark
Biobase
Origin
China
Production Capacity
1000units/Month

Product Description

Product Description

Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
Automatic Nucleic Acid Extraction System




 Introduction

Automatic nucleic acid extraction and purification system for the extraction of DNA or RNA from a variety of materials, such as whole blood, tissue, throat swab, etc., without centrifugation or filtrtion operation.

 


 

Detailed Photos

Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System

 

Product Parameters

Model
BNP96
Sample Capacity Screen
10.1 inch touch
Sample Volume
20-1000
Sample Capacity
1-96
Magnetic Bead Recovery
≥98%
Extraction Time
15- 40 minutes
Extracting the Differece Between Holes
CV≤3%
Consumption
500W
Operating Temperature
RT-120 ºC
Product Purity A260/A280
DNA≥1.7-2.0; RNA≥1.8-2.1
Shock Mlixing
Adjustable Speed (1-3)
Reagent Type
Open System for Magnetic Bead Method
Program Storage

Safety Door Design

Disinfection Method
≥100 groups
Safety door opened, the program operation will be automatically suspended,avoid cross-contamination

UV Light, Aerosol adsorption
Power Supply
AC100V-240V 50Hz/60Hz
External Size(W*D"H)
770*530"540mm
Package Size(W*D"H)
910*670*780mm
Gross Weight
95kg

Model

BK-HS96

Nucleic Acid Extraction Method

Paramagnetic particle method

Sample Capacity

96-well

Sample Volume

20-1000ul

Extraction Time

15min-60min

Magnetic Bead Recovery

≥98%

Magnetic Flux of Bar

3000-6000Gs,can change others

Operating Temperature

RT-105ºC

Shock Function

Yes

Temperature Accuracy

0.1ºC

Sample Protection Function

Power on self-check, power off protection, high-temperature alarm, over-temperature protection

Disinfection Method

UV  Light

Safety Door Design

The instrument is suspended when the safety door is opened

Operating System

Windows system

Scanning

Optional

Storage

>1000

Interface

USB interface

Power Supply

AC100-240V 50Hz/60Hz

Package Size(W*D*H)mm

1138*733*1028

Gross Weight(kg)

70


* High purity extraction, easy to operate and fully automated.
* High throughput, can process 1-96 samples at a time, save time.

* With professional extraction kit, extraction process optimization.
* Large program capacity, can store 1-100 groups of programs.
* With constant temperature function to ensure the best reaction temperature in the purification process.
* Friendly operation interface, easy to understand, no external computer, no special training.
* Compact appearance, solid material, long design life.

Company Profile

 

 

 

Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor SystemBiobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System
 

Contact me

Biobase PCR Clinical Diagnosis 96 Sample Capacity Nucleic Acid Extractor System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now