Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph

Product Details
After-sales Service: Online or Onsite
Warranty: 12 Months
Appliance: Biochemistry
Still deciding? Get samples of US$ 3500/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph
  • Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph
  • Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph
  • Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph
  • Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph
  • Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • After Sales Service
  • Recommended product by seller
  • Contact us
Overview

Basic Info.

Model NO.
BK-GC900
Ray Type
Gamma Ray Spectrometer
Gaspath System
Three
Detector
FID
Energy Resolution
≤7%
Spectrometer Detector
SDD
Stationary Phase
Solid Adsorbent
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
20~40mm
Product Name
Gas Chromatograph
Model
Bk-Gc900
Temp. Range
Rt+5~450
Temp. Accuracy
0.1
Temp. Program
20-Phase
Max. Temp. Heating Rate
40/Min
Time Range
0-655min
Internal Size
250*270*170mm
Detector1
Fid
Detector2
Tcd
Detector3
Fpd
Injection Method
Various Injection Methods Are Available:
Power Supply
AC220V, 50/60Hz
Standard Accessory
Fid Detector, Chromatography Workstation Software,
Optional Accessory
Sample Injection System
Transport Package
Wooden Packing
Specification
750*710*720mm
Trademark
BIOBASE
Origin
China
Production Capacity
10000pieces/Year

Product Description

Gas Chromatograph

Product Description

Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph

 

Application:
The product is widely used in medicine, optics, chemistry, food, cosmetics, electronic health, biological products, aerospace and
other fields
 

Feature:

 
* Ethernet communication interface is adopted, so that the instrument can realize long-distance data transm ssion through the internal LAN of the enterprise,which is convenient for the management of analysis data
* The unique design of the injection port solves the injection discrimination, and the dual-column compensation function not only solves the baseline drift caused by temperature programming, but also reduces the infuence of background noise, which canlead to lower detection limits.
* Unique vaporization chamber design, smaller dead volume; replacement of accessories such as injection pad,liner, polarizer,collector, nozzle can be done with one hand; packed column, capillary injector, TCD, FID detector and other main bodiesThereplacement only requires a wrench to be completely disassembled, and the maintenance is very convenient.
* The intelligent rear door system has stepless variable inlet and outlet air volume, which shortens the stable balance time of the system after programmed heating/cooling
* The inlet can be installed up to 4 types (packed column, capillary column splitsplitiess injection system can be used),multiple detectors with the same or different detectors are installed, automaticlmanual gas injection device can be selected.top Empty sampler, thermal desorption sampler, pyrolysis furnace sampler, methane reformer, etc.
* The instrument is equipped with a 4.3-inch color LCD touch screen and keyboard input for user operation
* Adopt the dual-stable gas path design of primary pressure stabilizer valve and stabilizer valve/pressure stabilizer valve
* With seven temperature control devices, the temperature control accuracy is lower than ±0.1ºC
* With double over-temperature protection and power-off protection function
* With linkage trigger signal acquisition system
* With fault self-check and alarm function

Product Parameters

Model
BK-GC900
Oven
Temp. Range
RT+5~450ºC
Temp. Accuracy
≤±0.1ºC
Temp. Program
20-phase
Max. Temp. Heating Rate
40ºC/min
Time Range
0-655min
Internal Size
250*270*170mm
Detector
Hydrogen Flame Ionization Detector (FID)
Detection limit:≤5×10-12g/s
(100ng/(µl n-hexadecane-isooctane solution)
Temperature 450ºC
Compatible with packed and capillary columns
Baseline drift:≤2x10-13A/30min
Baseline noise: 3×10-14A
Linear range:≥107
Thermal Conductivity Detector (TCD)
Sensitivity: >5000mv.ml/mg
(50mg/ml toluene-benzene solution)
Temperature 400ºC
Baseline drift:≤0.1mV/30min
Baseline noise: 0.03mV
Linear range:≥105(±10%)
Flame Photometric Detector (FPD)
Detection limit:≤5×10-12g/s(S of 10ng/(µl methyl parathion-ethanol solution)
Detection limit:≤4×10-12g/s(P of 10ng/(µl methyl parathion-ethanol solution)
Linear range (S): ≥103
Linear range (P): ≥104
Temperature 350ºC
Injection Method
Various injection methods are available:
1) Packed column injection;
2) Packed column gasification injection;
3) Capillary split/splitless injection: back pressure valve control technology, linear split;
4) Six-way valve gas injection;
5) On-line injection: continuous injection for 24 hours without supervision
Power Supply
AC220V±10%, 50/60Hz
Standard Accessory
FID detector, Chromatography workstation software, Capillary sampler
Optional Accessory
Sample injection system, TCD, FPD detector, Chromatographic column, Nickel catalytic converter
External Size(L*W*H)
530*502*508mm
Net Weight
42kg
Package Size (W*D*H)
750*710*720mm
Gross Weight
60kg

Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph

Delivery time
In stock ,can be shipped immediately after payment
Delivery time
3-7 days after payment

Company Profile


Biobase Chromatography Laboratory Gc Fid Detector Gas ChromatographBiobase Chromatography Laboratory Gc Fid Detector Gas ChromatographBiobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph

Biobase Chromatography Laboratory Gc Fid Detector Gas ChromatographBiobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph

After Sales Service

Biobase Chromatography Laboratory Gc Fid Detector Gas ChromatographBiobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph

Recommended product by seller

Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph

Contact us

Biobase Chromatography Laboratory Gc Fid Detector Gas Chromatograph



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More