Classification: Biological Diagnostics
Type: Auto Elisa Processor
Group: All
Product Name: Auto Elisa Processor
Sample Racks: 12*16 Push-Pull Sample Rack with Detection
Sampling Channel: 4 Channe
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (23)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Contact me
Overview

Basic Info.

Model NO.
BIOBASE4001
Liquid Level Detection
Air Pressure Level Detection, Clot Detection
Reagent Position
6 Reagent Racks, Reagent Tanks with Detection
Washer
2 Units
Washing Head
16-Channel (32-Pin), Double Row Cleaning
Reading Channels
8 Independent Photometric Channels,
Linear Range
0.000-3.000ABS
Incubators
12 Shaking Incubators
Cover Positions
2 (12 Covers)
Heating Method
Dry Heating with Cover
Temperature Range
Rt to 60 °c
Temperature Uniformity
0.5ºC
Disinfection
UV Lamp
Transport Package
Wooden Case or Carton Package
Specification
1775*190*1683mm
Trademark
Biobase
Origin
China
Production Capacity
1000units/Month

Product Description

Auto ELISA Processor BIOBASE 4001

Product Description

Biobase Ivd Analyzer 552 Sample Positions Fully Automatic Detection System Elisa Processor for Hospital


 


 

Introduction:
Auto ELISA Processor BIOBASE4001 is a fully automaticdetection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widelyused in hospital laboratories, disease prevention andcontrol centers, blood centers, and blood banks, animaland plant inspection and quarantine institutions, scientificresearch institutions, university laboratories and otherplaces.

Feature:
1.Adopt the principle of pressure type liquid detection.
2. With TIP detection, clot detection function.
3.High-precision pipetting, the lowest volume can reach 5ul.
4. Position sensing,real-time monitoring of gripper status.
5. Multi-spacing and multi-strength adjustable grippers can be adapted to grasp and place microplates andplate covers of different sizes.
6. Dual thread control, can run simultaneously with the sampling arm without interfering with each other.
 Biobase Ivd Analyzer 552 Sample Positions Fully Automatic Detection System Elisa Processor for Hospital

Product Parameters

 
 
Model
BIOBASE4001
Sample& Reagent Unit
Sample Racks
12*16 push-pull sample rack with detection
Sampling Channel
4 channels
Liquid Level Detection
Air pressure level detection, clot detection function
TIP
1000μl, 5 TIP racks
Pipetting
5μl~1000μl
Pipetting Precision
100μl: CV≤0.5%, Accuracy≤2.0%
1000μl: CV≤0.5%,Accuracy≤0.5%
Reagent Position
6 Reagent racks, reagent tanks with detection
Washing Unit
Washer
2 units
Washing Head
16-channel (32-pin), double row cleaning, hanging installation, with leakage recovery
Injection Uniformity
CV < 1.5%
Washing Residual
<1μl
Reading Unit
Reading Channels
8 independent photometric channels, mono and dichromatic reading
Linear Range
0.000-3.000Abs
Repeatability
CV≤1.0%
Stability
≤±0.003Abs
Optical Filters
4 standard filters (405,450,492,630nm);
Total 10 filters positions
Reading Accuracy
≤±0.02Abs from 0.0 to 1.0 OD,
≤±0.03Abs from 1.0 to 2.0 OD
Sensitivity
≥0.01mg/L
Channel Difference
≤0.02Abs
Incubation Unit
Incubators
12 shaking incubators
Cover Positions
2 (12 covers)
Heating method
Dry heating with cover
Shaking Function
Horizontal circular oscillation, 1-3 levels adjustable, amplitude 2.5mm
Temperature Range
RT to 60 °C
Temperature Uniformity
0.5ºC
Temperature Fluctuation
±0.5ºC
Data Management
Software
Above Windows 7 system
LIS System
Bi-direction, support HL7 protocol
Results
Absorbance and results reviewable by software
Printer
External optional
Built-in Scanner
Optional
Other Function
Biosafety Protection
Optional (Negative pressure working zone, HEPA filter)
Disinfection
UV lamp
Lighting
LED
IAP Function
Firmware can be upgraded online at any time
Working Condition
Power Supply
AC220V±10%,50/60Hz(Standard); 110V±10%,60Hz( Optional)
Temperature
10~40ºC
Humidity
30~80%
Size & Weight
External Size (W*D*H)
1775*190*1683mm
Net Weight
445kg
Package Size(W*D*H)
Machine: 1915*930*1150mm;
Base Stand: 1905*920*995mm
Accessories: 1370*930*530mm
Gross Weight
Machine: 364.5 kg; Base stand: 208.5 kg;Accessories: 97kg

Company Profile


Biobase Ivd Analyzer 552 Sample Positions Fully Automatic Detection System Elisa Processor for HospitalBiobase Ivd Analyzer 552 Sample Positions Fully Automatic Detection System Elisa Processor for Hospital

Contact me

 

Biobase Ivd Analyzer 552 Sample Positions Fully Automatic Detection System Elisa Processor for Hospital

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now