Classification: | Biochemical Apparatus |
---|---|
Type: | Biochemistry Analyzer |
Group: | All |
Still deciding? Get samples of US$ 8588/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product characteristics:
The risk of medical staff is small, reducing the probability of droplet infection.
It's fast and takes only 10 minutes to produces results.
No special testing environment and personnel training is required.
Compared with nucleic acid test swabs and pharyngeal swabs, it is less affected by samples and has high accuracy.
Dosage is less, only 1 drop of serum or plasma sample is needed.
Testing IgM and IgG at the same time to reduce the testing time.
Convenient, fast, suitable for mass screening.
Introduction:
When the human body is infected with the , the first antibody produced is the specific Igm antibody, which is generally produced after 3-7days of infection, and is replaced by a large number of specific IgG antibodies produced about two weeks later. Therefore, IgM and IgG of the specific antibodies can be used as an auxiliary means for the diagnosis of suspected patients.(Not Available in the U.S)
Product Name
|
Fluorescence Quantitative PCR Detection System
|
|||
Model
|
LEIA-X4
|
|||
Sample Capacity
|
96x0.1ml PCR plate, 12x8-strip tubes, 96*0.1ml single tube (Transparent Cover)
|
|||
Reaction System
|
10~50
|
|||
Dynamics Range
|
1-1010 copies
|
|||
Channel
|
4
|
|||
Emission Light
|
LED
|
|||
Detector
|
MPPC
|
|||
Detection Path
|
F1
|
F2
|
F3
|
F4
|
Suitable Probe/Dye
|
FAM/SYBR GREEN
|
VIC/JOE/ HEX/TET
|
ROX/TEXAS-RED
|
Cy5
|
Excitation Wavelength
|
455~680nm
|
|||
Detection Wavelength
|
510~730nm
|
|||
Fluorescence Detection Repeatability
|
CV≤2%
|
|||
Fluorescence Detection Accuracy
|
CV≤3%
|
|||
Fluorescence Detection Linearity
|
r≥0.995
|
|||
Module Temp. Range
|
4-99ºC(resolution:0.1ºC)
|
|||
Ramp Rate
|
5.0ºC/s(max)
|
|||
Temp. Accuracy
|
±0.3ºC
|
|||
Temp. Uniformity
|
≤ ±0.3ºC
|
|||
Temp. Control Mode
|
Block mode
|
|||
Gradient Temp. Range
|
1-36ºC
|
|||
Hot-Lid Temp. Range
|
100ºC, Automatic Hot-lid
|
|||
Scanning Mode
|
Full plate scanning
|
|||
Programming
|
Max 100 Segments for Each Program, Max 99 Cycles
|
|||
Operation Mode
|
Continuous
|
|||
Scanning Time
|
8.5s
|
|||
Special Function
|
Absolute quantitative automatic analysis, relative quantification, SNP Analysis, melting curve analysis, etc.
|
|||
Operation System
|
Microsoft: Windows10
|
|||
Power Supply
|
220V,50/60HZ; 110V,60HZ
|
|||
Dimension(L*W*H) Mm
|
375*490 *365
|
|||
Port Method
|
USB Port
|
|||
Packing Size(L*W*H) Mm
|
645*565 *605
|
|||
Gross Weight
|
45
|