After-sales Service: | Online Technical Support |
---|---|
Application: | Laboratory Apparatus |
Warranty: | 1 Year |
Detection Method: | Spectrophotometer |
Advantage: | High Vacuum |
Principle: | New Spectrometer |
Samples: |
---|
Suppliers with verified business licenses
Features;
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch screen
Display; Concave Grating.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED and xenon lamp.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm ~780nm. Built-in 400nm cut off/420nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.
7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users' requirement.
9.Multiple accessories, sample holders, fixation clamp, suitable to more working condition.
10, Big capacity data storage, for 20000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Model |
BK-GS6060 |
Optical Geometry |
Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; |
Application |
It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
Integrating Sphere Size |
Φ154mm |
Light Source |
360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nm Cut-off light source, UV Lamp |
Spectrophotometric Mode |
Concave Grating |
Sensor |
256 Image Element Double Array CMOS Image Sensor |
Wavelength Range |
360-780nm |
Wavelength Interval |
10nm |
Semi-band Width |
10nm |
Measured Reflectance Range |
0-200% |
Measuring Aperture |
Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Specular Component |
Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space |
CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN |
Color Difference Formula |
ΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1) , ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
Other Colorimetric Index |
WI (ASTM E313, CIE/ISO, AATCC, Hunter, YI (ASTM D1925, ASTM 313),TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index |
Observer Angle |
2°/10° |
Illuminant |
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Displayed Data |
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time |
About 2.4s (Measure SCI & SCE about 5s) |
Repeatability |
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) |
Inter-instrument Error |
Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles) |
Illuminant Life Span |
5 years, more than 3 million times measurements |
Display |
7-inch TFT color LCD, Capacitive Touch Screen |
Data Port |
USB & Bluetooth |
Data Storage |
Standard 5000 Pcs, Sample 40000 Pcs (One PCS can include both SCI and SCE) |
Language |
Chinese, English |
Operating Environment |
0~40ºC, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment |
-20~50ºC, 0~85%RH (no condensing) |
Standard Accessory |
White and Black Calibration Board, Checking Green Board, Sample Holder,∮4mm, ∮8mm, ∮15mm, ∮25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software |
Optional Accessory |
Micro printer, Transmissive Test Clamp Component |
Power Supply |
DC 24V, 3A; Power adapter: 110~230V 50/60HZ |
External Size(L*W*H) |
370*300*200mm |
Weight |
9.6kg |
Package Size (W* D*H) |
350*470*520mm |
Gross Weight |
18kg |
1.Why choose BIOBASE?
We are the leading manufactuer of biochemistry analyzer and reagent, OEM & ODM service are offered. And we have our own overseas techinican and installation team.
2.How about the sample of Biobase product?
We could send you the samples but the freight and the sample are charged.
3.How about Biobase payment term?
T/T & L/C &Alipay (40% deposit, the balance before shipment)
4.How about BIOBASE delivery time?
Within 3-15 workdays after receiving deposit.
5.How about BIOBASE validity of quotation ?
Usually 30 days as the shipping freight and exchange rate can be fluctuant.
6.What is the shipping port?
FOB to Qingdao Port,China(also can ship according to customers' request)
7.How about the package?
Bubble film + Cotton +Standard export wooden case for equipments. Bubble film + Cotton + Biological ice pack
8.How to inspect the goods?
Products will be checked by our QC staff frist, then our proejct manager. Client can come and check bythemselves or third party check is available.
Suppliers with verified business licenses