Theory: | Bjpx-C100ss |
---|---|
Type: | Ozone Ultraviolet Disinfection |
Certification: | CE, ISO13485 |
Still deciding? Get samples of US$ 18190/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Humanized Design
* The COz oscillation incubator integrates the CO2 incubator and the oscillation incubator. It has the advantages of small
floor space and large botle loading capacity.
* The color large touch screen display shows various parameters on one screen. The menu-style operation interface is
simple and easy to understand and operate. The operation interface has a password lock function to prevent human
misoperation and has a timing function.
* The new environmentally friendly design, brand compressors and air duct design have high efficiency, low energy con
sumption and low noise. They are not only energy-saving but also have a long service life. Compared with traditional
similar equipment, the cooling time can be reduced by more than 30%.
* The inner liner, vibration table and shelves are all made of 304 stainless steel. The four corners have a semi-circular arc
design. The inner liner wall is electrochemically treated, which can resist corrosion and avoid bacterial growth, ensuring
durability and facilitating cleaning and disinfection.
Powerful function design
* Carbon dioxide monitoring and control system
* Temperature and humidity control system
* Door temperature heating and monitoring system
* Ambient temperature monitoring system
* Three-eccentric shaft balanced drive
* Automatic control of circulating fan speed
* 90°C high-temperature moist heat sterilization system
Safety Functions
* The independent temperature limit alarm system can give audible and visual alarms to prompt the operator, ensuring the
safe operation of the experiment without accidents.
* It has alarms for low or high temperature and rotation speed, as well as over-temperature alarms, and alarms for excessively
high or low COz concentration.
* Itis equipped with safety failties such as alarms for excessive door opening time and reminders of the working status
of ultraviolet sterilization.
* When the box door is opened, the gentle air circulation, heating, and shaker automatically stop, without the disadvantage
of temperature overshoot.
* The control speed circuit can ensure the smooth start of the shaker and prevent instrument damage caused by liquid splashing.
* The independent temperature limit alarm system automatically cuts off heating when the limit temperature is exceeded
to ensure safe operation without accidents.
* The speed of the circulating fan is automatically contrlled to avoid sample volatilization caused by the overly fast circulating
fan during the experiment.
Model | BJPX-C100SS (Single layer) |
BJPX-C100DS (Double layer) |
BJPX-C300Ss (Single layer) |
BJPX-C300DS (Double layer) |
Capacity (L) | 120 | 220 | ||
Type | Air Jarket | |||
Display | LCD touch screen | |||
Temp.Range | RT-20~60ºC | |||
Temp.Fluctuation | ±0.1ºC | |||
Temp.Uniformity(ºC) | ±0.5ºC(at 37ºC) | |||
Herting Type | Six sides heating | |||
Refrigerant | R134a | |||
CO2 contro | IR sensor | |||
CO2 Range | 0~20% | |||
CO2 Control Resolution | ±0.1% | |||
CO2 Uniformity (vol%) | ±0.1% | |||
Stability of the CO2 | ±0.1%(@5%) | |||
CO2 Recovery Time | (Open the door for 30 seconds back up to 5%)<3 minutes | |||
Humidity Range | 50~95%RH | |||
Humidity Resolution | 0.1% | |||
Humidity Fluctuations | ±2%RH | |||
Humidity Control Precision | The humidity can reach 85%~95%at 37ºC,and the humidity is controlled in real time | |||
Time Setting | 0~999h59s | |||
Shaking Speed | 40~300rpm | |||
Shaking Accuracy | ±1 | |||
Vibration Range | 20mm | |||
Drive Mode | Three-eccentric shaft balanced drive type | |||
Loading Capacity | 10kg(Including clamps) | 15kg(Including clamps) | ||
Max.Capacity | 50ml*36 or 100ml*23 or 250ml*13 or 500ml*8 or 1L*5 or 2L*3 or 4L*1 or 5L*1(Flask camp) |
50ml*49 or 100ml*36 or 250ml*18 or 500ml*16 or 1L*9 or 2L*5 or 4L*4 or 5L*2(Flask camp) |
||
Tray Size(mm) | 350*350 | 450*450 | ||
Shelves | 1 pcs | |||
Filter | Microbe filter,HEPA filter | |||
Sterilization | 90ºC steam sterilization | |||
Power Supply | 220V,50Hz | |||
Consumption (W) | 1500 | 1800 | ||
Optional | RS232/485 interface and Communication software;CO2 reducing valve;Wireless alarm system (SMS alarm system);Printer;Hierarchical permission function |
|||
Internal Size(W*D*H)mm | 505*600*420 | 605*700*520 | ||