Capacity: | Three Person |
---|---|
After-sales Service Provided: | Engineers available to service machinery overseas |
Usage: | Research Institute, Hospital |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
PCR1600
|
PCR2100
|
PCR2500
|
|
External Size(L*W*H)mm
|
1600*710*1900
|
2100*710*2000
|
2500*850*2100
|
|
Reagent Preparation Area
|
Operating Area Size(L*W*H)mm
|
440*560*510
|
640*560*510
|
640*560*610
|
Pressure
|
Positive
|
|||
Airflow Velocity(m/s)
|
0.3-0.45
|
|||
Airflow Volume(m3/h)
|
190-290
|
290-430
|
380-560
|
|
Exhaust Type
|
-
|
|||
Specimen Preparation Area
|
Operating Area Size(L*W*H)mm
|
560*560*510
|
660*560*510
|
1060*560*610
|
Pressure
|
Negative
|
|||
Airflow Velocity(m/s)
|
Downflow: 0.33±0.025 Inflow: 0.53±0.025 |
|||
Airflow Volume(m3/h)
|
210
|
250
|
400
|
|
Exhaust Type
|
TypeA2, 30% exhaust, 70% recirculation
|
|||
Amplification Analysis Area
|
Operating Area Size(L*W*H)mm
|
440*560*510
|
640*560*510
|
640*560*610
|
Pressure
|
Negative
|
|||
Airflow Velocity(m/s)
|
≥0.4
|
|||
Airflow Volume(m3/h)
|
≥160
|
≥180
|
≥180
|
|
Exhaust Type
|
30% exhaust, 70% recirculation
|
100% exhaust
|
100% exhaust
|
|
ULPA Filter |
Four ,99.999% efficiency at 0.12μm.
|
|||
Clean Level
|
Class 100(IS0 Class 5)
|
Class 100, Except Amplification Analysis Area
|
||
Front Window
|
Manual, Toughened glass, Anti UV
|
|||
Max Opening
|
400mm
|
480mm
|
||
Noise
|
≤67 dB(A)
|
|||
Vibration
|
≤5μm
|
|||
UV Lamp
|
15W*3, UV timer, UV life indicator
|
15W*3, UV timer, UV life indicator
|
30W*1,15W*2
|
|
LED Lamp
|
4W*6
|
8W*6
|
8W*4,12W*2
|
|
Illumination(lx)
|
≥500( Each area)
|
≥650(Each area)
|
≥650(Each area)
|
|
Sockets
|
The load of two sockets (Each area): 500W, total 6 sockets
|
|||
Display
|
Touch Screen
|
|||
Control System
|
Microprocessor
|
|||
Visual and Audio Alarm
|
Filter replacement, window over height, abnormal air flow velocity
|
|||
Work Surface Height
|
750 mm
|
|||
Material
|
Work Zone: 304 stainless steel Main Body: Cold-rolled steel with anti-bacteria powder coating |
|||
Power Supply
|
AC220V±10%, 50/60Hz; 110V±10%, 60Hz
|
|||
Consumption
|
600W, total 2100W (With load)
|
1000W, total 2500W
|
||
Standard Accessory
|
LED lamp*6 UV lamp*4, Windproof plate*2(Only for PCR2100/2500), Waterproof sockets*6
|
|||
Package Size (W*D*H) |
1750*980*1400mm
|
2250*980*1400mm
|
2650*1120*1400mm
|
|
Gross Weight
|
400KG
|
450KG
|
500KG
|
Item
|
Name
|
Model
|
Quantity
|
Reagent preparation area
|
Pipette
|
0.5-10ul
|
1
|
Pipette
|
10-100ul
|
1
|
|
Pipette
|
100-1000ul
|
1
|
|
Centrifuge
|
MINI-7
|
1
|
|
Mixer
|
BJPX-VW
|
1
|
|
Tips
|
10ul,100ul, 1000ul
|
-
|
|
Centrifuge tube
|
1.5ml
|
-
|
|
8-strip tube
|
0.2ml
|
-
|
|
|
|
-
|
|
Specimen preparation area
|
Pipette
|
0.5-10ul
|
1
|
Pipette
|
10-100ul
|
1
|
|
Pipette
|
100-1000ul
|
1
|
|
Disposable Virus Sampling Collector (One Step method)
|
-
|
-
|
|
Tips
|
10ul,100ul, 1000ul
|
-
|
|
Centrifuge tube
|
1.5ml
|
-
|
|
Centrifuge
|
MINI-7
|
1
|
|
Mixer
|
BJPX-VW
|
1
|
|
Nucleic Acid Extraction System (only for PCR2500)
|
BNP32 or BNP8
|
1
|
|
Amplification analysis area
|
QPCR
|
FQD-96A
|
1
|
Other related equipment
|
Biosafety Transport Box
|
BTB-L5
|
1
|
-25ºC Freezer
|
BDF-25V270
|
1
|
|
-86ºC Freezer
|
BDF-86V158
|
1
|