After-sales Service: | Online |
---|---|
Warranty: | 1 Year |
Environment: | Normal Pressure and Temperature |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1,LCD display
2,Double control modes of box temperature and skin temperature
3,Double-layer thermostatic cover, automatic air curtain device
4,Humidity control function
5,Electronic elevator
6,Air & Oxygen blender
7,Oxygen supply system
8,Baby cot is infinitely adjustable
9,26 kinds of sound and light alarm, comprehensive protection of baby safety
parameters | Name | specifications |
Power supply requirement | AC220V/50Hz, 1320VA | |
Size(L*W*H) | 950*645*(1320-1520) mm | |
Maximum heater output power(220VAC) | Air chamber heater:350W; Water tank heater:150W | |
Auxiliary network power output | AC220V/50Hz, both maximum permissible currents are 220V 1.5A | |
Heater indication | 0~100%, 10% increasing amount | |
Temperature control mode | Tank temperature mode; skin temperature mode | |
Box temperature control range | 25.0~37.0ºC; 37.1~39.0ºC(Span mode) | |
Skin temperature control range | 34.0~37.0ºC;37.1~38.0ºC(Span mode) | |
Skin temperature sensor display range | 5.0~65.0ºC | |
Heating time | ≤ 30min | |
Temperature variability | ≤ 0.5ºC | |
Temperature uniformity (mattress in horizontal position) | ≤ 0.8ºC | |
Temperature uniformity (mattress in tilted position) | ≤1.0ºC | |
Difference between average incubator temperature and control temperature | ≤1.5ºC | |
Skin temperature sensor accuracy | ±0.3ºC | |
Humidity control | The running time of the tank after it is filled with distilled water | Humidity below 70%RH, at least 24h |
Water tank capacity | 1500ml | |
Humidity display range | 0%RH~99%RH | |
Humidity control range | CAH%RH~90%RH(1% per adjustment) | |
Humidity control accuracy | ±10% | |
Oxygen concentration control | Oxygen concentration display range | 0%~99% |
Oxygen concentration display resolution | 1% | |
Oxygen concentration control accuracy | ±5% oxygen volume concentration | |
Oxygen concentration setting range | 21% ~ 60% (1% per adjustment) | |
Oxygen sensor service life | Use up to 10,000h under 100% oxygen volume concentration | |
Transport storage | The temperature | -20ºC~+55ºC |
Atmospheric pressure range | 500hPa~1060hPa | |
Relative humidity | ≤93%RH | |
Packing size | Base packing size: 1200*850*920mm Body packing size: 1330*850*980mm |
|
The work environment | Relative humidity | 30%RH~75%RH |
Environment temperature | +20ºC~+30ºC | |
Pressure range | 800hPa~1060hPa | |
Service altitude | ≤2000m | |
Overvoltage category | II | |
Pollution level | 2 | |
Ambient air velocity | ≤ 0.3m/s | |
Other indicators | Ambient noise in the infant compartment of the incubator | No more than 55dB(A) at stable temperature |
Carbon dioxide concentration in the infant compartment | Input 4% carbon dioxide and air mixture at 750mL/min into the 8mm diameter pipe in the vertical direction from the mat to the top of the box to 10cm above the center of the mattress, and the concentration will be less than 0.5% after stabilization | |
The velocity of air flow over the baby mattress | ≤0.35m/s | |
General alarm |
Power failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarm | |
System alarm | Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failure |