Biobase Clean Booth Ducted Fume Hood for Lab

Product Details
Capacity: One Person
After-sales Service Provided: Engineers available to service machinery overseas
Usage: Research Institute, Hospital, School, Company
Still deciding? Get samples of US$ 749/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Biobase Clean Booth Ducted Fume Hood for Lab
  • Biobase Clean Booth Ducted Fume Hood for Lab
  • Biobase Clean Booth Ducted Fume Hood for Lab
  • Biobase Clean Booth Ducted Fume Hood for Lab
  • Biobase Clean Booth Ducted Fume Hood for Lab
  • Biobase Clean Booth Ducted Fume Hood for Lab
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • After Sales Service
  • FAQ
  • Contact Delia
Overview

Basic Info.

Model NO.
FH700
Noise
≤62DB
Type
Biological Safety Cabinet
Model
Fh700
External Size(W*D*H)
700*620*1150mm
Internal Size(W*D*H)
640*550*700mm
Max Opening
660mm
Air Velocity
0.3~0.8m/S
LED Lamp
4W *2
Blower
Built-in Centrifugal Blower; Speed Adjustable
Front Window
Folding Acrylic Window, Down Part with Free Stop F
Consumption
200W
Power Supply
AC220V±10%,50/60 Hz; 110V±10%,60 Hz
Optional Accessory
15W UV Lamp, HEPA Filter, Base Stand
Gross Weight Without Base Stand
100kg
Gross Weight with Base Stand
115kg
Package Size Without Base Stand(W*D*H)
840*760*1400mm
Package Size with Base Stand(W*D*H)
840*960*1400mm
Transport Package
Wooden Case
Specification
840*960*1400mm
Trademark
BIOBASE
Origin
China
Production Capacity
300unit/Month

Product Description

Product Description

Biobase Clean Booth Ducted Fume Hood for Lab

Fume Hood FH700: Negative pressure in work area protects operator and environment.


ADVANTAGE

1. Folding acrylic front window, down part with free stop function.

2. Microprocessor control system, LED display.

3. With memory function in case of power-failure.

4. Built-in centrifugal blower.

5. Interlock function: UV lamp and blower, LED lamp (Only for choosing UV lamp).

Note: Experiments with strong acids and alkali, flammable or explosive substances cannot be conducted with this type fume hood.

Product Parameters

Model                              

FH700

External Size(W*D*H)

700*620*1150mm

Internal Size(W*D*H)

640*550*700mm

Max Opening

660mm

Air Velocity

0.3~0.8m/s

Noise

≤65dB(A)

LED Lamp

4W *2

Blower

Built-in centrifugal blower; Speed adjustable

Front Window

Folding acrylic window, down part with free stop function

Material

Main Body

1.0mm cold-rolled steel with bacteria power coating

Work Table

Chemical resistant phenolic resin

Back&Side Windows

5mm toughened glass

Consumption

200W

Power Supply

AC220V±10%,50/60 Hz; 110V±10%,60 Hz

Standard Accessory

LED lamp, Active carbon filter, Blower, 4 meters PVC exhaust duct, Pipe strap

Optional Accessory

15W UV lamp, HEPA filter, Base stand

Gross Weight without Base Stand

100kg     

Gross Weight with Base Stand

115kg

Package Size without Base Stand(W*D*H)

840*760*1400mm

Package Size with Base Stand(W*D*H)

840*960*1400mm

Certifications

Biobase Clean Booth Ducted Fume Hood for LabBiobase Clean Booth Ducted Fume Hood for LabBiobase Clean Booth Ducted Fume Hood for Lab

Packaging & Shipping

Biobase Clean Booth Ducted Fume Hood for Lab

Company Profile

Biobase Clean Booth Ducted Fume Hood for Lab

After Sales Service

Biobase Clean Booth Ducted Fume Hood for Lab

FAQ

1.Why choose BIOBASE?
We are the leading manufactuer in lab furniture and lab equipment, OEM & ODM service are offered. And we have our own overseas techinican and installation team.
2.How about the sample of Biobase product?
We could send you the samples but the freight and the sample are charged.
3.How about Biobase payment term?
T/T & L/C &Western Union(40% deposit, the balance before shipment)
4.How about BIOBASE delivery time?
Within 7-15 workdays after receiving deposit.
5.How about BIOBASE validity of quotation ?
Usually 30 days as the shipping freight and exchange rate can be fluctuant.
6.What is the shipping port?
FOB to Qingdao Port,China(also can ship according to customers' request)
7.How about the package?
Bubble film + Cotton +Standard export wooden case.
8.How to inspect the goods?
Products will be checked by our QC staff frist, then our proejct manager. Client can come and check bythemselves or third partycheck is available.

Contact Delia

We focus on Fume Hood,we know what you need,just send your inquiry to us,we will try our best to support you.

Biobase Clean Booth Ducted Fume Hood for Lab

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More